Motorschutz

Protect motors from harmful overvoltage and dV/dt spikes

Motor Protection

Introduction

Motors controlled by VFDs or servo drives require additional attention to avoid overvoltage spikes, known as dV/dt. Voltage wave reflection is a function of the voltage rise time
(dV/dt) and the length of the motor cables. This phenomenon creates additional overvoltage spikes which cause premature degradation and failure to the motor insulation.

The challenge for OEMs, system integrators and distributors is to ensure the installed motors are well protected from overvoltage. Markets using VFDs have adopted a special motor, better known as, a motor rated VFD or inverter duty motor.

For more information, please visit: Motor protection application

Browse Motorschutzs

quick view

FIN47SNB
  • Nominal voltage 0 - 500 Vac
  • Reduces dV/dT
  • Remote contact indicator
  • Compact dimensions due to the parallel installation

quick view

FIN5955
  • Differential mode impedance
  • Rated currents from 3 - 20A
  • Nominal voltage 600 Vac
  • Low power loss up to 250 Hz frequency output
  • Protects against voltage spikes to the motor

quick view

FIN5980P
  • Rated currents from 9 - 22A
  • Nominal voltage 600 Vac
  • Differential mode impedance
  • Eliminates dV/dt
  • Overvoltage spikes regenerate into the DC bus

quick view

FIN5983
  • Rated currents from 12 - 60A
  • Nominal voltage 600 Vac
  • Differential mode impedance
  • Eliminates dV/dt
  • Footprint with drives manufacturers

quick view

FIN900
  • Asymmetrische Drossel
  • Nennstrom von 10 bis 280A
  • Nennspannung 500VAC
  • Hohe Impedanz
  • Reduzierung von hochfrequenten Störungen (PWM)
  • Mit Kabel- und Schraubanschluss erhältlich
FIN900.(010 - 030).C

quick view

FIN905SF
  • Sinusfilter
  • Nennstrom von 8 – 250A
  • du/dt Reduzierung
  • Verlängerte Motorlebensdauer

quick view

FIN915SFH
  • Sinusfilter für hohe Frequenzen
  • Nennstrom von 8 – 250A
  • du/dt Reduzierung
  • Verlängerte Motorlebensdauer
  • Sehr geringe Eigenerwärmung bei hochfrequentem Einsatz

quick view

FIN930
  • Asymmetrische Drossel
  • Nennstrom von 10 bis 200A
  • Nennspannung 600VAC
  • Niedrige Impedanz
  • Reduziert du/dt des Umrichtermotors
  • Garantiert lange Motorlebensdauer

quick view

FIN950U
  • Nennspannung 480 VAC
  • Frequenzbereich 50/60 Hz
  • Isolationsklasse H
  • Maximale Stromfrequenz 100 Hzu
  •  

quick view

FIN958
  • Rated current from 12 to 110A
  • Protects against voltage spikes to the motor
  • Low power loss up to 1 kHz frequency output

quick view

FIN960F
  • Glättungsdrossel für hohe Motorfrequenzen
  • Einsatz bei synchronen Motorspindeln
  • Keine Eigenerwärmung des Kerns
  • Hohe Linearität gegen Frequenz

quick view

FINSTP
  • Nominal voltage 600 Vac 
  • Reduces dV/dt 
  • Very low power loss 
  • Easy installation

quick view

FINTR / FINFE
  • Ringkerne
  • In unterschiedlicher Größe erhältlich
  • Ferrit mit hoher Permeabilität
  • Berührungsschutz durch Kunststoffabdeckung

Previous Category

Next Category

Full Page